energy efficiencyTurning on the TV nightly news in October 1973, you would have seen headlines about OPEC imposing an oil embargo on the U.S. and other western countries and Israel’s war with neighboring countries. The war lasted for 20 days, but its impact and that of a second oil embargo in 1979 is still with us today.

Overnight the price of crude oil increased from $3 to around $5 per barrel, and when OPEC, in early 1974, reduced production, the price increased to around $12 per barrel — then in 1980 to $39.50 (it was as high as $96.77 in 2015). Thus began the era of energy conservation that has led to today’s emphasis on energy efficiency and sustainability.

Having walked through more than 1,400 educational facilities in the past 17 years, I still see the remnants of energy conservation actions taken in the mid ‘70s in older buildings — blocked up window openings and reduced daylighting (smaller windows). Before 1973, electricity rates averaged about $0.019/kWh vs. today’s $0.104/kWh or $0.017/kWh in 1972 dollars. “Energy Conservation” echoed through the nation’s educational buildings in the mid ’70s through the ‘80s. What these words meant to the occupants was lower light levels, reduced natural light, cooler temperatures in the winter and warmer temperatures in the fall and spring, or simply stated, “What can you do without or endure to reduce energy use.” Common sense was lacking in the actions taken. For example, blocked-up windows and weather stripping of doors and windows resulted in bad indoor air quality and the need for more outside conditioned air, which resulted in higher energy use.

The emphasis on improving the energy efficiency of buildings and energy systems began in the 1990s, which consequently led to the development of design standards, known as Leadership in Energy & Environmental Design (LEED). Common sense was starting to affect building design, their energy systems and the learning environment.

Today, high-performance design for educational facilities in both new construction and renovations is the rule rather the exception. There are several design standards in use besides LEED: CHPS, Green Globes and local variants of each. Today, common sense is playing a role in the improvement of the energy efficiency of buildings and their systems.

As a result of energy audits over the past decade and a half, two statements were coined and should be remembered when dealing with improving energy efficiency in schools; 1) “the little overlooked energy inefficiencies add up; the big ones are found and corrected” and 2) “Buildings don’t operate themselves, People Do!” With these two statements in mind, I will point out areas where one can improve building efficiencies with ideas of what to do to achieve improvements using common sense.

Many building have had lighting upgraded from T-12 to T-8 to T-5 fluorescent lamps, and today to LED. But the difference in light levels resulting from these upgrades may have been overlooked. I know of one instance where the upgrade increased the lighting levels in the classroom significantly. De-lamping the classroom resulted in the removal of 15 lamps. Over the entire district, enough lamps were removed and placed in a warehouse and were reused to supply the district with lamps for several years — a “little thing” amounting to significant savings in both
energy and future resources.

Similarly, as I walk the hallways of schools and colleges, I notice the hallways are fully lit, and I am the only one there. Classes are not typically conducted in hallways, but hallway lights are normally on from 10 to 15 hours a day. Full lighting is needed only one to two hours a day. During the other hours a reduced light level is adequate. This change would result in a significant energy reduction and an overall increase in lighting systems efficiency. It can be accomplished in two ways: Control of lighting in hallways/ hallway segments with the use of occupancy sensors or, 2) Control the lighting according to the class changing schedule or other similar system — another “little thing” with big energy reductions.

Staying on the topic of hallways, here three more areas where you can improve efficiency. First, many hallways provide walkways for students and staff from one part of the school or campus to another, possibly with windows on one or both sides providing natural daylighting. Controlling this lighting should be by use of daylight sensors during the day. Second, normally outside entrances to gyms, auditorium and other buildings are well lit with large window areas that provide significant daylighting, but these lights are on. There should be occupancy and/or daylight sensors controlling these lights — again, a “little thing”. And third, if the building is secured by an alarm system, what is the need to have lighting left on when the last person leaves? A secure building with no occupants has no need for lighting. The night lighting circuit should be controlled by the security system. Once the alarm is set, the lights should go off, after a delay, and only turn on and act as a deterrent if that security is breached.

Back to the classrooms, lecture halls, etc., the lighting should be controlled by occupancy and daylight sensors. If possible, only one light switch should be placed at the entrance. Other switches should be placed as far away from the door as possible. The HVAC systems, especially the air-handling units for the spaces should also be controlled by occupancy sensors. There is no reason to have fresh outside air be introduced if no one is there. That’s just common sense.

Plug loads can account for up to 25 percent of the electrical usage in a building. Proper use of the equipment — turning it off when not in use or leaving the room for the day is common sense. When equipment is plugged in but not turned on, energy is being used. It is called “phantom loads” or “vampire loads.” There is a way to control phantom loads in a building with the use of Bye Bye Standby devices. They are a socket adaptor that completely cuts power to the electric devices plugged into it when they’re not in use, thus saving the power that electric devices would otherwise consume in Standby Mode. They are available at an economical price.

Here is one example. LCD projectors in classrooms are mounted on the ceiling. When the units are “off” they still consume energy. It has been determined that over a year the average projector is used about one hour per day, 365 days a year or 2 hours a day during the school year. The “off” time results in about 42 kWh wasted annually if is not properly controlled or disconnected from electricity when not in use. This can be controlled by a custodian with a remote using Bye Bye Standby devices as he or she walks down the hallway at the end of the day. A school with 24 classrooms can save more than 900 kWh that would have been wasted annually by LCD projectors. A “little thing” solved by using common sense.

To reduce the impact of phantom loads on the overall energy consumption in a building, when it is closed for breaks or vacations, use common sense and unplug the equipment. In an effort to control plug loads, the National Electric Code writers are considering requiring that, in new construction, 50 percent of all outlets in a room be controlled by occupancy sensors. A similar concept has been in use in Europe for a couple of decades.

Another source of energy inefficiency that unfortunately resides behind closed doors is the source of the electrical energy to the outlets throughout the building. This source is known as a Low Voltage Distribution Transformer (LVDT). The inefficiency of the older and minimum-standard LVDT amounts to significant wasted energy. For example, the annual electrical energy wasted in a typical elementary school resulting from an older LVDT is approximately 30,000 kWh.

A new minimum standard for LVDT has been established by U.S. Department of Energy and goes into effect on Jan. 1, 2016. More efficient LVDTs meeting and exceeding DOE 2016 minimum standards, with better matching load profiles are currently being manufactured.

Based on the statement “Buildings don’t operate themselves, People DO!!”, the success of correcting the “little things” will be determined by the effectiveness of an energy awareness program. A successful Energy Awareness Program should be directed at all segments of the school or college’s population — students, teachers and administrators. A student awareness program should be included in daily activities. Energy can be incorporated in science, math, language arts and history curriculum. The awareness should begin at the lowest level — kindergarten. Starting at this level will ensure that a solid foundation of understanding energy efficiency is developed for their future and the nation’s.

Energy Awareness training for teachers and administrators should make them aware, in simple terms, of how the building energy systems operate and their limitations. Review those “little things” and asking them to report any other “little things” which appear to be wasting energy. Encourage them to use their common sense. This training should include how their actions can saves energy or be contributing to energy waste. Addressing how the waste/energy inefficiency is impacting the resources available will be key in their overall understanding. All administrators and instructional personnel should have at least two training sessions annually.

The purpose of this article is to provide the background, insight and a few ideas about how to improve, maintain and sustain the energy efficiency of educational facilities today and in the future. These ideas and insights will prepare your facilities for achieving the next step in the energy efficiency movement that began in 1973 — Zero Net Energy (ZNE). Common sense should be used and encouraged to improve a building’s energy efficiency will be evident and lasting.

This article originally appeared in the issue of .

Featured

  • American University Launches Sustainability Research Project

    American University in Washington, D.C., recently began a research project exploring the relationship between purchase decisions for university campuses and sustainability, according to a news release. The study seeks to explore how “greening” the purchases involved in student housing renovations, breaking ground on new facilities, buying new equipment and supplies, and more, can foster larger sustainability goals.

  • Saint Francis University Opens Aviation Education Center

    Saint Francis University in Loretto, Penn., recently held a Blessing and Dedication ceremony for its new Aviation Education Center at the John Murtha Johnstown-Cambria County Airport, according to a news release. The building’s opening coincides with the inaugural year of the university’s FAA-certified Aviation Maintenance Technician (AMT) program.

  • Georgia State University Plans Campus Transformation

    Georgia State University in Atlanta, Ga., recently received an $80-million gift that will go toward the largest campus transformation project in university history, according to a news release. The contribution from the Robert W. Woodruff Foundation will go toward a planned $107 million in campus upgrades across nine projects in downtown Atlanta.

  • University of Kentucky Opens New Design Building

    The University of Kentucky in Lexington, Ky., recently held a ribbon-cutting ceremony for the Gray Design Building, the new home for the College of Design. The renovated building formerly served as a tobacco warehouse that had been empty for years, according to a news release.

Digital Edition