A Few Tips

In many parts of the country, our schools are located in the foothills of mountains. And, as we have seen most recently in California, our schools are also located in the path of wildfires.Wildfires have a natural cycle of clearing debris from the forest floor. With a change in policy to aggressively fight manmade wildfires, we have inadvertently added to the fuel load of the forests on or near our campuses. The result is that fires are burning hotter, bigger, and faster than ever. Because of the intensity of the fires we see today, schools must consider how to create defensible spaces around the infrastructure of utilities, structures, and land uses they have in the urban-wildland interface.

Fire damage statistics prove that locations that take into account proactive approaches to mitigate wildfire damage see lower losses than locations that don’t. In 2013, a fire in Colorado’s Black Forest saw 61 out of 67 structures lost while a nearby development with robust wildfire risk reduction planning lost only four structures.

Fire Risk Reduction for our Campuses Should Include:

Specifying materials and construction methods to reduce risk of ignition. Consider the combustible characteristics of the materials chosen for structures in the urban-wildland interface zone. Most reputable manufacturers will submit their products to UL for testing and classification related to their combustibility. Designers should specify materials that are listed as non-combustible. I would suggest project managers select design firms that have past experience designing structures in this unique environment.

In addition to material selection, contractors should discuss their plan of construction for the facility. Project managers should demand that the general contractor and all subcontractors submit plans for reducing the risk of fire during construction. Once plans are submitted, they should be reviewed by local fire officials, or if they are not available, seek input from fire inspectors with experience in fire risk reduction in the urban-wildland interface.

Separating structures by a minimum of 30 feet. Creating larger distances between structures can reduce fire spread from one structure to another. A brief search of fires that spread from one structure to another will demonstrate the impacts of radiant heat. Creating distances reduces the radiant heat threat.

Extending water supplies for fire departments well past structures and to a fire break in the landscape. Investing in the installation of water supplies that extend past structures and up to firebreaks will allow for quicker fire suppression efforts. Schools that abut parks should consider extending water supply into the park. Doing so allows fire departments to fight closer to the fire and not closer to the school. It is also necessary to invite local fire department crews to tour locations when you install this infrastructure. They need to exercise the lines, valves, and understand what the limitations (if any) are of this unusual setup.

Planning open space and recreational trails in campus gardens that create fire breaks and provide access paths suitable for fire vehicle passage. Fire department risk reduction specialists are unanimous in their call for creation of firebreaks to separate developed areas from natural spaces. They will also champion your efforts to create pathways that are wide enough for local fire vehicles and that are created with materials that can support the weight of suppression equipment. Without firebreaks or access paths, fire officials have little choice but to defend from locations that are accessible.

Maintenance programs to keep vegetation from overgrowing fire breaks. A tour of several schools located in the foothills of mountains around their campus showed a clear need to keep vegetation cleared from buildings and from overtaking established firebreaks. Planners and landscape architects should design grounds that have a minimum of 50 feet of space around structures or other significant areas.

Strict enforcement of policies prohibiting use of open flame and other activities that can start fire. A careful review of uses permitted in the urban-wildland zone must be undertaken on a regular basis. Special events large or small, as well as class-based activities, must be weighed against the risk of fire during all seasons. What may be accepted in the spring while land and vegetation is still moist may not be acceptable during the summer when all moisture is gone.

These are just a few tips. Consult state Fire Marshal offices for guidance specific to your area or reach out to the many fire safety consultants who can help you navigate your options to reduce the risk of wildfire and its impact on your facilities.

This article originally appeared in the School Planning & Management May 2018 issue of Spaces4Learning.

About the Author

Mike Halligan is the President of Higher Education Safety, a consulting group specializing in fire prevention program audits, strategic planning, training and education programs and third party plan review and occupancy inspections. He retired after twenty six years as the Associate Director of Environmental Health and Safety and Emergency Management at the University of Utah. He frequently speaks and is a recognized expert on residence hall/student housing fire safety and large scale special event planning. He also works with corporate clients to integrate products into the campus environment that promote safety and security.

Featured

  • Spaces4Learning Launches Redesigned Website

    Spaces4Learning, the publication impacting K–12 & higher-education environments, a part of Converge360, a division of 1105 Media, is pleased to announce the redesign of its website, spaces4learning.com.

  • Colorado State University Starts Construction on Liberal Arts Building Renovation

    Colorado State University in Fort Collins, Colo., recently began construction on a $137-million renovation project to one of its largest academic buildings, according to local news. Last week, one of the three wings of Clark Hall (“Clark B”) was demolished to clear the way for a ground-up replacement.

  • NRC Issues Construction Permit for Molten Salt Reactor at Texas University

    The Nuclear Regulatory Commission (NRC) recently issued a construction permit to Abilene Christian University in Abilene, Texas, to build the Natural Resources molten salt reactor, according to a news release. The Natura MSR-1 will become the first NRC-licensed liquid fueled salt reactor in U.S. history and the first U.S. university research reactor that has been approved in more than 30 years.

  • Massachusetts High School to Build New Athletics Facility

    Middlesex School, which serves boarding and day students in grades 9–12, recently moved forward with plans to build a new athletics facility for its campus in Concord, Mass., according to a news release. MassDevelopment recently issued a $43.7-million tax-exempt bond to fund the project.

Digital Edition