Emergency Egress Plans

I have been working with many campuses this year in updating their emergency egress plans. As we looked at the best routes out of each building it became apparent that not all egress routes were created equal. Specifically, egress routes can evolve over time just as much as the programs in the rooms. It reminded the team of evaluators that it is important to review existing buildings periodically and determine if changes in use, configuration of corridors or room configurations have an impact on required egress routes. We also found instances where evacuation floor plans gave wrong information based on updates to fire alarm systems, areas of refuge and secondary exits. In other locations egress windows did not meet the clear opening size as required by fire codes.

Emergency Egress Route Plan

The 2015 Fire Code has specific requirements for maintenance of egress routes and the signs posted to graphically show occupants what safety equipment and routes they have available to them. Graphics for emergency evacuation plans should depict, at a minimum, the following: primary and secondary egress routes, fire extinguisher locations, pull station locations (remove from locations without), emergency assembly points (EAP) located away from the building, severe weather shelter location(s) within the building, building name and postal service address, instructions to report fires and other emergencies, areas of refuge, directions to not use elevators and guidelines to assist persons with special needs.

Furniture Layout

Many buildings have wide corridor and lobby areas. Over time, the configuration of furniture can change. It is important to review the placement of new furniture and verify it does not obstruct egress paths. There are creative methods that can be used to help occupants keep furniture in the correct place. For example, varying carpet or tile colors can be used to designate acceptable and unacceptable locations.

Catering and special event operations often set up tables and chairs in corridors and rooms. Pre-approving acceptable setup scenarios will increase compliance with fire code egress requirements.

Egress Windows

Many locations make use of emergency escape and rescue windows in residential occupancies. There were two common problems identified during the evacuation plan update. First, some windows did not meet the minimum required opening or were too high off the floor. Ground-floor windows must have five square feet of opening, and those on upper floors a minimum of 5.7 square feet. Some locations had windows that had the correct opening, but poor maintenance did not allow the window to fully open. Several campuses had buildings where the height of the window exceeded 44 inches or did not meet minimum width (20 inches) or height (24 inches). Other locations had added grilles or bars for security. If these security features are added they must be operational from inside the room without the use of keys or tools. Rooms with window security features must also have smoke detectors installed.

Lessons learned at all locations this summer can be summarized as follows: existing buildings must have egress routes and egress diagrams reviewed periodically. Reviews should be completed when new flooring is installed, programmatic changes occur or when alarm systems or sprinkler systems are installed. Exterior site changes requiring new emergency assembly points must include an update to interior diagrams directing occupants to a location.

There are many other requirements related to maintaining safe egress systems. The items listed here reflect common problems identified at many schools. Every campus should create a timeline to evaluate both the physical components of as well as user-related impacts to the egress system.

This article originally appeared in the College Planning & Management September 2016 issue of Spaces4Learning.

About the Author

Mike Halligan is the President of Higher Education Safety, a consulting group specializing in fire prevention program audits, strategic planning, training and education programs and third party plan review and occupancy inspections. He retired after twenty six years as the Associate Director of Environmental Health and Safety and Emergency Management at the University of Utah. He frequently speaks and is a recognized expert on residence hall/student housing fire safety and large scale special event planning. He also works with corporate clients to integrate products into the campus environment that promote safety and security.

Featured

  • Springfield Breaks Ground on $53.7M Pipkin Middle School Rebuild

    Construction is underway on a new, state-of-the-art Pipkin Middle School in Springfield, Mo., a major step in Springfield Public Schools’ (SPS) long-term facility improvement plan, according to local news. The $53.7-million project officially broke ground in early June, following years of planning and community input aimed at modernizing aging infrastructure and addressing student capacity concerns.

  • ProTeam Launches GoFit 6 HEPA Backpack Vacuum

    Technology leader Emerson recently introduced the new ProTeam GoFit 6 HEPA backpack vacuum, according to a news release. The vacuum was designed to capture 99.97% of particulates down to 0.3 microns—including atmospheric hazards like lead dust, mold spores, and other particulates—through an advanced filtration system.

  • California High School Starts Construction on New CTE Building

    Analy High School, part of the West Sonoma County Union High School District (WSCUHSD) in Sebastopol, Calif., recently broke ground on a new Career Technical Education (CTE) Building, according to a news release. The 15,000-square-foot facility will offer specialized facilities for students in engineering, welding, culinary arts, agricultural sciences, and design thinking.

  • modern college building with circuit and brain motifs

    Anthropic Introduces Claude for Education

    Anthropic has launched a version of its Claude AI assistant tailored for higher education institutions. Claude for Education "gives academic institutions secure, reliable AI access for their entire community," the company said, to enable colleges and universities to develop and implement AI-enabled approaches across teaching, learning, and administration.

Digital Edition